Ajax 12v PSU for Hub & Rex
R462.00 Incl. VAT
Ajax 12v PSU for Hub (1), Hub Plus (1) & Rex(1) | 8-20v Input Voltage
The Ajax 12v PSU is a power supply unit used to connect the Hub, Hub Plus and ReX units to low-voltage power sources such as a 12V power supply or portable battery. An ideal solution for premises with no electricity, unstable power, mobile homes or boats.
The 12v PSU replaces the on-board 220v PSU.
- Input voltage: 8 – 20 VDC
- Output voltage: 4.65 VDC ± 3%
- Switch on voltage: 8 VDC ± 2.5%
- Switch off voltage: 6.9 – 7.5 VDC (depending on load)
- Max input current: < 1 A
- Max output current: 1.5 A
- DC jack: (Female) 6.5 × 2 mm | (Male) 5.5 × 2.1 mm
- Dimensions: 138 × 64 × 13 mm
Description
Ajax 12v PSU for Hub (1), Hub Plus (1) & Rex (1)
A power supply unit used for connecting the Hub, Hub Plus control panels and ReX radio signal range extender to low-voltage power sources.
In Warehouses, Building Sites etc:
Use Ajax in premises lacking electricity or having an unstable power supply. A 12 V power supply unit allows connecting hubs and radio signal extenders to low-voltage networks or use a portable battery.
In Campervans and Caravans:
Ajax protects your home, even if it goes on wheels. Connect the hub to a car or portable battery and let the security system travel with you.
On Yachts:
Insert a SIM card and connect the hub to the on-board network or battery so that Ajax always guards your boat at the pier.
Compatibility:
The power supply unit is compatible with Hub, Hub Plus, and ReX. It features a standard socket for connecting the power jack plug and has a bundled terminal adapter.
Installation:
12V PSU is installed into the device body replacing the pre-installed 110/230 V power supply unit.
Ajax 12v PSU for Hub User Manual and Tech Specs
Additional information
Weight | 30 g |
---|---|
Dimensions | 138 × 64 × 13 mm |
Calculate Power Consumption
How to calculate the time of operation of the central panel from an external battery:
Divide the capacity of the external battery by the power consumption of the central panel.
Power consumption of the central panel depends mostly on active communication modules — the average values are indicated in the table:
Central panel | Active communication modules | Average input current |
Hub | GSM | 42 mA |
Ethernet | 80 mA | |
GSM+Ethernet | 90 mA | |
Hub Plus | GSM | 35 mA |
Ethernet | 72 mA | |
GSM+Ethernet | 93 mA | |
Wi-Fi | 20 mA | |
Wi-Fi+GSM | 42 mA | |
Wi-Fi+Ethernet | 80 mA | |
Wi-Fi+GSM+Ethernet | 96 mA | |
Hub 2 | GSM | 33 mA |
Ethernet | 80 mA | |
GSM+Ethernet | 86 mA | |
ReX | — | 20 mA |
For instance, when connected to a 40A·h battery, Hub 2 — with active GSM module only — will operate approximately 1200 hours (40A·h / 0.033A).